2.14 PROGram Subsystem
2-27
2.14 PROGram subsystem
GW APS-1102 PROG Exec.vi
This controls sequence operations. Control is performed using the STOP (stop), START (run),
HOLD (hold), BRANCH0 (branch 0), or BRANCH1 (branch 1) parameter.
When in AC-EXT, AC-SYNC, AC+DC-EXT, or AC+DC-SYNC mode, sequences cannot be executed.
([3,"Invalid in this mode"] error occurs.)
When output OFF, sequence execution is disabled. ([2,"Invalid with output off"] error occurs.)
<Input>
Select Execute
This sets the sequence operation control status. The default setting is “STOP”.