MEASure HLIMIT FREQuency <Index>?
*Only for the version V1.18 and
above.
MEAS:HLIMIT:FREQ^1?
20 MHz
MEASure HLIMIT LEVEL <index>
<value>
*Only for the version V1.18 and
above.
Index:0,1,2……..9
Value:-180~+20 dBm
MEAS:HLIMIT:LEVEL^1^-10
OK
MEASure HLIMIT LEVEL <index>?
*Only for the version V1.18 and
above.
MEAS:HLIMIT:LEVEL^1?
-10 dBm
MEASure HLIMIT EDIT OK
*Only for the version V1.18 and
above.
MEAS:HLIMIT:EDIT:OK
OK
MEASure HLIMIT DELETE ALL
*Only for the version V1.18 and
above.
MEAS:HLIMIT:DELETE:ALL
OK
MEASure LLIMIT FREQuency <index>
<value>
*Only for the version V1.18 and
above.
Index:0,1,2……..9
Value:0 to 2700MHz
MEAS:LLIMIT:FREQ^1^5
OK
MEASure LLIMIT FREQuency <index>?
*Only for the version V1.18 and
above.
MEAS:LLIMIT:LEVEL^1?
5 MHz
MEASure LLIMIT LEVEL <index>
<value>
*Only for the version V1.18 and
above.
Index:0,1,2……..9
Value:-180~+20 dBm
MEAS:LLIMIT:LEVEL^2^-20
OK
MEASure LLIMIT LEVEL <index>?
*Only for the version V1.18 and
above.
MEAS:LLIMIT:LEVEL^2?
-20 dBm
MEASure LLIMIT EDIT OK
*Only for the version V1.18 and
above.
MEAS:LLIMIT:EDIT:OK
OK
MEASure LLIMIT DELETE ALL
*Only for the version V1.18 and
above.
MEAS:LLIMIT:DELETE:ALL
OK
MEASure ALARM PASS?
*Only for the version V1.18 and
above.
MEAS:ALARM:PASS?
OK
CONtrol BW AUTO 100 Assign BW in ALL AUTO mode CON:BW:AUTO
OK
CONtrol RBW <index> 200 Assign the RBW in index number 2=3kHz, 4=30kHZ, 6=300kHZ, 7=4MHz.
Optional:3=9kHz, 5=120kHz
CON:RBW^4
OK
CONtrol RBW AUTO 100 Assign the RBW in auto mode CON:RBW:AUTO
OK