<NR3>
-12.00 ~ +12.00, with 0.00 being the center
division.
Example
:MATH:POS 3.00
Sets the position to the
3
rd
division above the
center division.
:MATH:FFT:SOURce
Set
Query
Description
Sets the source channel for FFT math.
Syntax
< Long >
< Short >
:MATH:FFT:SOURce
{CH1|1|CH2|2}
:MATH:FFT:SOURce?
:MATH:FFT:SOUR
{CH1|1|CH2|2}
:MATH:FFT:SOUR?
Parameters
CH1|1
Channel 1
CH2|2
Channel 2
Example
:MATH:FFT:SOUR 1
Sets the source to CH1
:MATH:FFT:WINDow
Set
Query
Description
Sets FFT window type.
Syntax
< Long >
< Short >
:MATH:FFT:WINDow
{HANning|0|FLATtop|1|RECTa
ngular|2|BLAckman|3}
:MATH:FFT:WIND
{HAN|0|FLAT|1RECT|2
|BLA|3}
Parameters
HANning|0
Hanning window
FLATtop|1
Flattop window
RECTangular|2
Rectangular window
BLAckman|3
Blackman window
Example
:MATH:FFT:WIND HAN
Sets the window type