GDS-1000A-U Programming Manual
60
Before any Go-NoGo command can be used,
please use the :GONogo:FUNCtion 1 command to
initialize the oscilloscope.
:GONogo:SOURce {1|2}
:GONogo:SOURce?
:GON:SOUR {1|2}
:GON:SOUR?
Parameter/
Return parameter
Sets the source to channel 1
Sets the source to channel 2
Sets the source to
channel 1.
Sets or queries the Go-NoGo violation conditions.
Before any Go-NoGo command can be used,
please use the :GONogo:FUNCtion 1 command to
initialize the oscilloscope.
:GONogo:VIOLation {0|1}
:GONogo:VIOLation?
:GON:VIOL {0|1}
:GON:VIOL?
Parameter/
Return parameter
Violation condition = “Continue”
Violation condition = “Stop”
Sets the violation
condition to
“Continue”.
Sets or queries the Go-NoGo template mode.
When Auto mode is selected, CH1 or CH2 are
used as the template source. When Normal mode
is selected, the template source can be selected
from internal memory (W1~W15, RefA or RefB).
Comentarios a estos manuales