Gw-instek GOM-802 Programming Manual Manual de usuario Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
DC MILLI-OHM METER
PROGRAMMER MANUAL
18
z Status Commands
Table 3 lists the status commands that set and query the various
registers and queues that make up the status and event structure of the
Meter.
Table 3: Status Commands
*CLS Clears the status data structures.
*ESE <NR1>
Sets the Event Status Enable Register
(ESER).
*ESE?
Returns contents of Event Status Enable
Register (ESER).
*ESR? Returns and clear the contents of
Standard Event Status Register (SESR).
*SRE <NR1> Sets contents of Service Request
Enable Register (SRER).
*SRE? Returns contents of Service Request
Enable Register (SRER).
*STB? Reads Status Byte Register (SBR).
:STATus:OPERation:CONDition? Returns the contents of the OPERation
condition register. Returns NR1.
:STATus:OPERation:ENABle
<NR1>
Sets the contents of the enable mask for
the OPERation event register.
:STATus:OPERation:ENABle? Returns the contents of the enable mask
for the OPERation event register.
Returns NR1.
DC MILLI-OHM METER
PROGRAMMER MANUAL
19
:STATus:OPERation:EVENt? Query the contents of the OPERation
Event register.
:STATus:PRESet Presets the OPERation and
QUEStionable status registers.
:STATus:QUEStionable:CONDition? Returns the contents of the OPERation
condition register. Returns NR1.
:STATus:QUEStionable:ENABle
<NR1>
Sets the contents of the enable mask
for the QUEStionable enable register.
:STATus:QUEStionable:ENABle? Query the contents of the
Questionable Enable register.
:STATus:QUEStionable:EVENt? Query the contents of the
QUEStionable Event register.
z Miscellaneous Commands
Table 4 lists the miscellaneous commands that control general
housekeeping functions of the Meter.
Table 4: Miscellaneous Commands
*IDN? Returns instrument identification.
*OPC Reports when the operation is completed by
setting the Operation Complete bit in SESR.
*OPC? Reports when operation is completed. Same as
*OPC except returns a 1 to the output queue
and dose not set the SESR bit.
*RST Resets states, sets ohm function.