COMMAND DETAILS
95
:PROGram:SEQuence
Program Number
Specific
Description
Sets the Sequence number for the current program
number.
Syntax
:PROGram:SEQuence <NR1>
Parameter
<NR1>
Sequence number
1~10
Number 1~10
Example
:PROG:SEQ 1
Sets the sequence
number to 1 for the
current program
number.
Query Syntax
:PROGram:SEQuence?
Return Parameter
<NR1>
Mainframe Scanning
1-10
Returns the current
sequence number
Query Example
:PROG:SEQ?
1
The set sequence
number is 1.
:PROGram:MEMory
Program Number
Specific
Description
Sets the memory number used for the current
program/sequence.
Syntax
:PROGram:MEMory <NR1>
Parameter
<NR1>
Memory number
1~120
Number 1~120
Example
:PROG:MEM 1
Sets the memory number
to 001.
Query Syntax
:PROGram:MEMory?
Return Parameter
<NR1>
Mainframe Scanning
1-120
Returns the current
program number