COMMAND DETAILS
33
:measure:pduty?
:meas:pdut?
Returns
<NR2> as the percentage
Note
Before using this command, select the
measurement channel. See the example below.
Example
:measure:source 1
:measure:pduty?
Selects Channel 1, and
then measures the
positive duty cycle.
:MEASure:PERiod
Query
Description
Returns the period.
Same as: Measure key F1~F5 F3 (Period)
Syntax
< Long >
< Short >
:measure:period?
:meas:per?
Returns
<NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:measure:source 1
:measure:period?
Selects Channel 1, and
then measures the
period.
:MEASure:PWIDth
Query
Description
Returns the first positive pulse width.
Same as: Measure key F1~F5 F3 (+Width)
Syntax
< Long >
< Short >
:measure:period?
:meas:per?
Returns
<NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Vista de pagina 32