COMMAND DETAILS
43
Example :measure:source 1
:measure:vhi?
Selects Channel 1, and
then measures the
global high Voltage.
:MEASure:VLO
Query
Description
Returns the global low voltage.
Same as: Measure key → F1~F5 → F3 (Vlo)
Syntax
< Long > < Short >
:measure:vlo? :meas:vlo?
Returns <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example :measure:source 1
:measure:vlo?
Selects Channel 1, and
then measures the
global low Voltage.
:MEASure:VMAX
Query
Description
Returns the maximum amplitude.
Same as: Measure key → F1~F5 → F3 (Vmax)
Syntax
< Long > < Short >
:measure:vmax? :meas:vmax?
Returns <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example :measure:source 1
:measure:vmax?
Selects Channel 1, and
then measures the
maximum amplitude.
GDS-1000A Programming Manual
44
:MEASure:VMIN
Query
Description
Returns the minimum amplitude.
Same as: Measure key → F1~F5 → F3 (Vmin)
Syntax
< Long > < Short >
:measure:vmin? :meas:vmin?
Returns <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example :measure:source 1
:measure:vmin?
Selects Channel 1, and
then measures the
minimum amplitude.
:MEASure:VPP
Query
Description
Returns the peak-to-peak amplitude (difference
between maximum and minimum amplitude)
Same as: Measure key → F1~F5 → F3 (Vpp)
Syntax
< Long > < Short >
:measure:vpp? :meas:vpp?
Returns <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example :measure:source 1
:measure:vpp?
Selects Channel 1, and
then measures the
peak-to-peak
amplitude.