COMMAND DETAILS
15
Example :lrn?
:DISPlay:WAVeform 0;ACCumulate 0;CONTrast 0;GRATicule
0;:CHANnel1:DISPlay 1;BWLimit 0;COUPling 0;INVert
0;OFFSet 2.000e+00;PROBe 3;SCALe
2.000e+00;:CHANnel2:DISPlay 1;BWLimit 0;COUPling
0;INVert 0;OFFSet 2.000e+00;PROBe 3;SCALe
2.000e+00;:CHANnel1:MATH 0;:TIMebase:SWEep 0;SCALe
2.500e-06;DELay 0.000e+00;WINDow:SCALe 2.50000e-
07;DELay 0.00000e+00;:ACQuire:MODe 0;AVERage
0;:TRIGger:TYPe 0;SOURce 0;MODe 1;SLOP 0;COUPle 1;REJect
0;NREJ 0;LEVel 0.00000e+00;PULSe:MODe: 0;TIMe
0.00000e+00;:VIDeo:TYPe 1;POLarity 0;FIELd 0;LINe
0;:CURSor:SOURce 1;XDISPlay 0;X1Position 75;X2Position
175;YDISPlay 0;Y1Position 54;Y2Position 154;:REF1:DISPlay
0;LOCate 50;:REF2:DISPlay 0;LOCate -50;:RUN
*RST
Set
Description
Resets the GDS-1000A (recalls the default panel
settings).
Same as: Save/Recall key → F1
Syntax *rst
:SYSTem:ERRor
Query
Description
Returns the oscilloscope system error message, if
there is any.
Syntax
< Long > < Short >
:system:error? :syst:err?
Parameter
ID
Contents
ID
Contents
-100
command error
-102
syntax error
-220
parameter error
-221
settings conflict
-222
data out of range
-223
too much data
-224
illegal parameter
-232
invalid format
Example :system:error?
-102
Indicates that the
command syntax is
wrong
GDS-1000A Programming Manual
16
:SYSTem:VERSion
Query
Description
Returns the oscilloscope firmware version.
Same as: Utility key → F4 (only the firmware
version)
Syntax
< Long > < Short >
:system:version? :syst:vers?
Note
For retrieving all system information including the
firmware version, use the *idn? command.