COMMAND DETAILS
45
:MEASure:VRMS
Query
Description
Returns the root-mean-square voltage.
Same as: Measure key → F1~F5 → F3 (Vrms)
Syntax
< Long > < Short >
:measure:vrms? :meas:vrms?
Returns <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example :measure:source 1
:measure:vrms?
Selects Channel 1, and
then measures the root
mean square voltage.
GDS-1000A Programming Manual
46
Save/Recall Command
:MEMory<X>:RECall:SETup ........................................ 46
:MEMory<X>:RECall:WAVeform ................................. 46
:MEMory<X>:SAVe:SETup .......................................... 47
:MEMory<X>:SAVe:WAVeform ................................... 47
*RCL ............................................................................. 48
:REF<X>:DISPlay .......................................................... 48
:REF<X>:LOCate .......................................................... 49
:REF<X>:SAVe .............................................................. 49
*SAV ............................................................................. 50
:MEMory<X>:RECall:SETup
Set
Description
Recalls a panel setting from the internal memory.
Same as: Save/Recall key (recall) → F3
Syntax
< Long > < Short >
:memory<x>:recall:setup :mem<x>:rec:set
Parameter <X>
Internal memory
1 ~ 15 S1 ~ S15
Example :memory1:recall:setup
Recalls the settings from
the internal memory S1
:MEMory<X>:RECall:WAVeform
Set
Description
Recalls a waveform from the internal memory and
saves it to a reference waveform.
Same as: Save/Recall key (recall) → F4
Syntax
< Long > < Short >
:memory<x>:recall:waveform
<NR1>
:mem<x>:rec:wav
<NR1>
Parameter <X>
Internal memory
Comentarios a estos manuales