Gw-instek GDS-3000 Series Programming Manual Manual de usuario Pagina 44

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 103
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 43
GDS-3000 Programming Manual
44
Example
:MATH:DUAL:POSition 1.0E+0
Sets the vertical position to 1.00 unit/div.
:Math:DUAL:POSition?
1.0E+0
Returns the position as 1.00 unit/div.
:MATH:DUAL:SCALe
Set
Query
Description
Sets the vertical scale of the displayed math result.
Syntax
:MATH:DUAL:SCALe {<NRf>|?}
Parameter
<NRf>
Vertical scale
Depends on the vertical scale
Return parameter
Returns the scale as <NR3>
Example
:MATH:DUAL:SCALe 2.0E-3
Sets the vertical scale to 2mV/2mA.
:MATH:DUAL:SCALe?
2.0E-3
Returns the unit/div scale (2mA).
:MATH:FFT:SOURce
Set
Query
Description
Sets and queries the FFT source.
Syntax
:MATH:FFT:SOURce
{CH1|CH2|CH3|CH4|REF1|REF2|REF3|REF4|?}
Parameter
CH1~4
Channel 1 to 4
REF1~4
Reference waveform 1 to 4
Return parameter
Returns the FFT source.
Vista de pagina 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 102 103

Comentarios a estos manuales

Sin comentarios