Gw-instek GDS-3000 Series Programming Manual Manual de usuario Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 103
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
GDS-3000 Programming Manual
62
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:PDUTy?
5.000E+01
Selects Channel 1, and then measures the positive
duty cycle.
:MEASure:PERiod
Query
Description
Returns the period.
Syntax
:MEASure:PERiod{?}
Return parameter
Returns the period as <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:PERiod?
1.0E-3
Selects Channel 1, and then measures the period.
:MEASure:PWIDth
Query
Description
Returns the first positive pulse width.
Syntax
:MEASure:PWIDth{?}
Return parameter
Returns the first positive pulse width as <NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH 1
:MEASure:PWIDth?
5.0E-6
Selects Channel 1, and then measures the positive
pulse width.
Vista de pagina 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 102 103

Comentarios a estos manuales

Sin comentarios