COMMAND DETAILS
71
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:FALL?
Selects Channel 1 as the source, and then measures
the fall time.
:MEASure:PWIDth
Description
Returns the first positive pulse width.
Syntax
:MEASure:PWIDth?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the positive pulse width.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:PWIDth?
5.0E-6
Selects Channel 1, and then measures the positive
pulse width.
:MEASure:NWIDth
Description
Returns the first negative pulse width timing.
Syntax
:MEASure:NWIDth?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the negative pulse width in
seconds.
Query
Query
Vista de pagina 70