COMMAND DETAILS
73
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the number of positive pulses.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:PPULSE?
6.000E+00
Selects Channel 1, and then measures the number
of positive pulses.
:MEASure:NPULSE
Description
Returns the number of negative pulses.
Syntax
:MEASure:NPULSE?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the number of negative pulses.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:NPULSE?
4.000E+00
Selects Channel 1, and then measures the number
of negative pulses.