GDS-200 & GDS-300 Programming Manual
82
Example
:MEASUrement:MEAS1:SOURCE1
CH1
Returns the (first) source for measurement 1.
:MEASUrement:MEAS<X>:TYPe
Description
Sets or queries the measurement type for a selected
automatic measurement. This is a statistics related
command.
Syntax
:MEASUrement:MEAS<X>:TYPe
{PK2pk | MAXimum | MINImum | AMPlitude | HIGH |
LOW | MEAN | CMEan | RMS | CRMs | AREa | CARea |
ROVShoot | FOVShoot | RPReshoot | FPReshoot |
FREQuency | PERIod | RISe | FALL | PWIdth | NWIdth |
PDUTy | PPULSE | NPULSE | PEDGE | NEDGE
| FRRDelay | FRFDelay | FFRDelay | FFFDelay |
LRRDelay | LRFDelay | LFRDelay | LFFDelay | PHAse
| ?}
Related
commands
:MEASUrement:MEAS<X>:SOURCE<X>
Parameter
MEAS<X>
The automatic measurement number
from 1 to 4.
Return parameter
Returns the measurement type
Example
:MEASUrement:MEAS1:TYPe RMS
Sets measurement 1 to RMS measurement.
:MEASUrement:MEAS<X>:VALue
Description
Returns the measurement results for the selected
measurement. This is a statistics related command.
Syntax
:MEASUrement:MEAS<X>:VALue?
Related
Commands
:MEASure:SOURce<X>
:MEASUrement:MEAS<x>:TYPe
Set
Query
Query
Vista de pagina 81