Vista de pagina 32
GDS-806/810/820/840 Programming Manual
32
:CHANnel<X>:SCALe
Sets or query the vertical scale of the specified channel.
Syntax
:CHANnel<X>:SCALe <NR3>
:CHANnel<X>:SCALe?
Arguments
<X>Specify the channel number (1|2)
<NR3> is the desired gain value in volts per division. The range is 2mV/div to 5V/div
(with 1X probe).
Next table shows the relationship between the <NR3> value and matching scale.
0.002Æ2mV 0.01Æ10mV 0.1Æ100mV 1Æ1V
0.005Æ2mV 0.02Æ20mV 0.2Æ200mV 2Æ2V
0.05Æ50mV 0.5Æ500mV 5Æ5V
Returns
<NR3>
Examples
:CHANnel1:SCALe 1, setup the channel one at 1V per division.