GDS-806/810/820/840 Programming Manual
68
:TRIGger:VIDeo:FIELd
Select and query the field on which the video trigger mode will be triggered.
Syntax
:TRIGger:VIDeo:FIELd <0|1|2>
:TRIGger:VIDeo:FIELd?
Arguments
0Line 1Odd frame (Field 1)
2Even frame (Field 2)
Returns
<NR1>
:TRIGger:VIDeo:LINe
Select and query the specified line for video signal.
Syntax
:TRIGger:VIDeo:LINe <NR1>
:TRIGger:VIDeo:LINe?
Arguments
<NR1> is the desired line.
For NTSC system, the range of line is from 1~263 for Odd frame, 1-262 for even
frame.
For PAL system, the range of line is from 1~313 for Odd frame, 1-312 for even
frame.
Returns
<NR1>