Gw-instek GDS-800 Series Programming Manual Manual de usuario Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 89
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
GDS-806/810/820/840 Programming Manual
50
:TEMPlate<X>:UPLoad (Available for firmware 2.0 and above only)
Upload the user-defined template to the assigned location.
Syntax
:TEMPlate1:UPLoad#3548………
Format:
The string of data is following.
# Data size
digit
Data size Package
type
Template
number
Position Text string Reserved Check
sum
Template
data
#: Begin a transmission of data string.
Data size digit: Indicate the digits of following data string amount(1 digit), The
value is ‘3’ in ASCII code.
Data size: The amount of current data string (3 digits). The value is “548” in ASCII
code.
Package type: The GO/NO-GO template package type (1 bytes). The value is
0x03 in hex.
Template number: The location of template stored in memory. The valid range is
from 1 to 100 dots. The content is a single byte in hex (0x01 ~ 0x64).
Position: The position of template. The valid range is from -300 to +300 dots. The
content is a two bytes signed integer in hex (0xFED4 ~ 0x012C). (2 bytes, high byte
first)
Text string: The user defined string that will be shown on the screen. Here we
support English only. The string must include an ending character 0x00. (39
bytes).
Reserved: This location is reserved for future usage. (1 bytes).
Check sum: The check sum value is coming from the sum of 500 bytes of template
data. This value is 32 bits unsigned integer in hex (4 bytes, high byte first).
Vista de pagina 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 88 89

Comentarios a estos manuales