GDS-806/810/820/840 Programming Manual
63
:TRIGger:LEVel
Select and query the trigger level.
Syntax
:TRIGger:LEVel <NR3>
:TRIGger:LEVel?
Arguments
<NR3> is the desired trigger level voltage.
Returns
<NR3>
:TRIGger:MODe
Select and query the trigger mode.
Syntax
:TRIGger:MODe <0|1|2|3>
:TRIGger:MODe?
Arguments
0→Auto Level
1→Auto
2→Normal
3→Single
Returns
<NR1>