Gw-instek GDS-2000A series Programming Manual Manual de usuario Pagina 115

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 272
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 114
COMMAND DETAILS
115
Timebase Commands
:TIMebase:EXPand ....................................................115
:TIMebase:POSition ..................................................115
:TIMebase:SCALe .......................................................116
:TIMebase:MODe ......................................................116
:TIMebase:WINDow:POSition ..................................116
:TIMebase:WINDow:SCALe ......................................117
:TIMebase:EXPand
Description
Sets or queries the horizontal expansion mode.
Only available for firmware V1.18 or above.
Note
Requires the Horizontal Expansion app. Available
for download on the GW Instek website.
Syntax
:TIMebase:EXPand {CENTer|TRIGger|?}
Parameter/Return
parameter
CENTer
Expand from the center of the
display.
TRIGger
Expand from the trigger point.
Example
:TIMebase:EXPand TRIGger
Sets the expansion point to the trigger point.
:TIMebase:POSition
Description
Sets or queries the horizontal position.
Syntax
:TIMebase:POSition {<NRf> | ?}
Parameter
<NRf>
Horizontal position
Return parameter
<NR3>
Returns the horizontal position.
Example
:TIMebase:POSition 5.00E-4
Sets the horizontal position as 500us.
Set
Query
Set
Query
Vista de pagina 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 271 272

Comentarios a estos manuales

Sin comentarios