COMMAND DETAILS
159
:TRIGger:BUS:B1:LIN:IDentifier:VALue
Description
Sets or returns the binary address string to be used
for the LIN trigger.
Note: Only applicable when the condition is set to
DATA or IDANDDATA.
Requirements: Firmware version V1.19 or later with
DS2-LA8 (or DS2-LA16).
Syntax
:TRIGger:BUS:B1:LIN:IDentifier:VALue {<string>|?}
Parameter/
Return parameter
<string>
The size of the string depends on the
data size setting. The string must be
enclosed in double quotes, “string”.
String contents:
x = don’t care
1 = binary 1
0 = binary 0
Example
:TRIGger:BUS:B1:LIN:CONDition ID
:TRIGger:BUS:B1:LIN:IDentifier:VALue "00X1X01X"
:TRIGger:BUS:B1:LIN:IDentifier:VALue?
>01100X1X01X