COMMAND DETAILS
91
Return parameter
<NR3>
Returns the amplitude.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:AMPlitude?
3.76E-3
Selects Channel 1, and then measures the
amplitude.
:MEASure:MEAN
Description
Returns the mean voltage/current of one or more
full periods.
Syntax
:MEASure:MEAN{?}
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the mean.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:MEAN?
1.82E-3
Selects Channel 1, and then measures the mean
value.
:MEASure:CMEan
Description
Returns the mean voltage/current of one full
period.
Query
Query