Gw-instek GDS-2000A series Programming Manual Manual de usuario Pagina 136

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 272
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 135
GDS-2000A Programming Manual
136
:TRIGger:BUS:B1:I2C:ADDRess:MODe
Description
Sets or queries the I
2
C addressing mode (7 or 10
bits).
Syntax
:TRIGger:BUS:B1:I2C:ADDRess:MODe {ADDR7 |
ADDR10 | ? }
Related
commands
:TRIGger:BUS:B1:I2C:CONDition
Parameter
ADDR7
7 bit addressing
ADDR10
10 bit addressing
Return Parameter
0
7 bit addressing
1
10 bit addressing
Example
:TRIGger:BUS:B1:I2C:ADDRess:MODe?
0
The addressing mode is current set to 7 bits.
:TRIGger:BUS:B1:I2C:ADDRess:TYPe
Description
Sets the I
2
C bus address type, or queries what the
setting is.
Syntax
:TRIGger:BUS:B1:I2C:ADDRess:TYPe {GENeralcall |
STARtbyte | HSmode | EEPROM | CBUS | ?}
Related
commands
:TRIGger:BUS:B1:I2C:CONDition
Parameter
GENeralcall
Set a general call address (0000 000 0).
STARtbyte
Set a start byte address. (0000 000 1)
HSmode
Set a high-speed mode address.
(0000 1xx x)
EEPROM
Set an EEPROM address.
(1010 xxx x)
CBUS
Set a CBUS address. (0000 001 x)
Set
Query
Set
Query
Vista de pagina 135
1 2 ... 131 132 133 134 135 136 137 138 139 140 141 ... 271 272

Comentarios a estos manuales

Sin comentarios