REMOTE CONTROL
135
[:SENSe]:FREQuency:CENTer
Set
Query
Description
Sets or queries the center frequency.
Syntax
[:SENSe]:FREQuency:CENTer <freq>
Query Syntax
[:SENSe]:FREQuency:CENTer?
Parameter
<freq>
<NRf>
Return parameter
<NR3>
Hz
Example
FREQ:CENT 1.0e+9
[:SENSe]:FREQuency:CENTer:STEP
Set
Query
Description
Sets or queries the CF Step frequency.
Syntax
[:SENSe]:FREQuency:CENTer:STEP <freq>
Query Syntax
[:SENSe]:FREQuency:CENTer:STEP?
Parameter
<freq>
<NRf>
Return parameter
<NR3>
Hz
Example
FREQ:CENT:STEP 1.0e+3
[:SENSe]:FREQuency:CENTer:STEP:AUTO
Set
Query
Description
Turns the CF Step frequency setting to auto (on) or
manual (off) or queries its state.
Syntax
[:SENSe]:FREQuency:CENTer:STEP:AUTO
{OFF|ON|0|1}
Query Syntax
[:SENSe]:FREQuency:CENTer:STEP:AUTO?
Parameter
0
Turn CF Step to manual (off).
1
Turn CF Step to auto (on).
OFF
Turn CF Step to manual (off).
ON
Turn CF Step to auto (on).
Return parameter
0
CF Step is set to manual.
1
CF Step is set to automatic.