REMOTE CONTROL
193
UNIT Commands
:UNIT:PMETer:POWer ...................................................... 193
:UNIT:POWer ....................................................................... 193
:UNIT:PMETer:POWer
Set
Query
Description
Sets the amplitude unit used for the Power Meter
mode.
Syntax
:UNIT:PMETer:POWer {DBM|MW}
Query Syntax
:UNIT:PMETer:POWer?
Parameter/
Return parameter
DBM
Decibels
MW
Milliwatts
Example
:UNIT:PMET:POW DBM
:UNIT:POWer
Set
Query
Description
Sets the amplitude unit used for the Spectrum
mode.
Syntax
:UNIT:POWer {DBM|DBMV|DBUV|W|V}
Query Syntax
:UNIT:POWer?
Parameter/
Return parameter
DBM
Decibels
DBMV
decibels relative to one millivolt
DBUV
decibels relative to one microvolt
W
Watt
V
Volt
Example
:UNIT:POW DBM