COMMNAND OVERVIEW
125
:FSEQuence:EDIT:END?
Set
Query
Description
Returns the number of points in the sequence.
Query Syntax
:FSEQuence:EDIT:END?
Return parameter
<NR1>
1~1000
Query example
:FSEQuence:EDIT:END?
> 20
Indicates that there are 20 steps in the sequence.
:FSEQuence[:DELet]:ALL
Set
Description
Deletes all the data points for the fast sequence.
Syntax
:FSEQuence[:DELet]:ALL
Example
:FSEQuence:ALL
:FSEQuence[:EDIT]:FILL
Set
Query
Description
The FILL function is used to evenly fill up the
current or resistance value settings from a starting
step to a finishing step. This function is equivalent
to entering the FUNC>Sequence>Fast
Sequence>Edit Sequence>Fill menu.
Syntax
:FSEQuence[:EDIT]:FILL
{<NR2>,<NR2>,<NR1>,<NR1>}
Query Syntax
:FSEQuence[:EDIT]:FILL?
Related
Commands
:FSEQuence:EDIT