PEL-3000 Programming Manual
28
*ESE 8
Sets bit 3 of the ESE register.
*ESE?
>12
Bits 2 and 3 are set in the Standard Event Status
Enable register.
Reads the Standard Event Status register. This
command will also clear the Standard Event Status
register.
*ESR?
>48
Bits 4 and 5 are set in the Standard Event register.
Queries the manufacturer, model number, serial
number, and firmware version of the instrument.
Returns the instrument identification as a
string in the following format:
GW-INSTEK, PEL-3021, XXXXXXXX, V.VV
Manufacturer: GWINSTEK
Model number : PEL-3021
Serial number : XXXXXXXX
Firmware version : V.VV