PEL-3000 Programming Manual
42
MINIMUM or MIN
MAXIMUM or MAX
LIMIT or LIM
Minimum current limit
value.
MAXimum current limit
value.
Limit the load
Returns a string with OCP setting followed by the OCP
value.
:OCP LIM
Sets the OCP setting to limit.
:OCP 77.000
Sets the OCP value to 77A.
:OCP?
>LIMIT, 77.000
The OCP setting is LIMIT and the OCP value is
77.000A.
Sets or queries the OPP trip settings. The OPP limit
can be set to a specific value or the trip setting can
be set to either limit the power or to turn the load
off.
[:CONFigure]:OPP {<NRf> [W] | MINimum |
MAXimum | LIMit | LOFF }
MINIMUM or MIN
MAXIMUM or MAX
LIMIT or LIM
MINIMUM power limit
value.
MAXIMUM power limit
value.
Limit the load
Returns a string with OPP setting followed by the OPP
value.