COMMNAND OVERVIEW
163
-168 Block data not allowed
A legal block data element was
encountered but was not allowed
by the device at this point in
parsing.
-170 Expression error
This error is generated when
parsing an expression data
element.
-171 Invalid expression
The expression data element was
invalid.
-178 Expression data not allowed
A legal expression data was
encountered but was not allowed
by the device at this point in
parsing.
-180 Macro error
This error is generated when
defining a macro or executing a
macro.
-181 Invalid outside macro
definition
Indicates that a macro parameter
placeholder ($<number) was
encountered outside of a macro
definition.
-183 Invalid inside macro definition
Indicates that the program
message unit sequence, sent with
a *DDT or *DMC command, is
syntactically invalid.
-184 Macro parameter error
Indicates that a command inside
the macro definition had the
wrong number or type of
parameters.